PRODUCT SPECIFICATIONS
● Size ------ 1220x200mm
● Thickness ----- 10mm
● Wear Layer ------ AC4
● Installation ------ Floating
Your location:
High quality of pinewood used for producing the5mm HDF . Pinewood have the advantage oflow water swelling rate because it is with highcontent of wood grease
● High quality of pinewood used for producing the5mm HDF . Pinewood have the advantage oflow water swelling rate because it is with highcontent of wood grease.
● More important , Furen group self-developedadhesive technology . Environmental development and application of the urine aldehyde resineffectively protect the wood fiber keep awayfrom water.
● Meanwhile , urine aldehyde resin reduce the re-lease of formaldehyde during the productionprocess , to ensure the HDF can reach CARB2level formaldehyde release.
Testing Standard : LY/T1739-2009 Decorative Wooden Flooring
Test Item | Unit | Standard | VHP flooring (Both face 7mm) | WSPC (One face 6mm) | Engineered flooring ( 15mm ) | |||||
Floor Grade | Results | Conclusion | Results | Conclusion | Results | Conclusion | ||||
First Grade | Qualified Product | Qualified Product | Qualified Product | Qualified Product | ||||||
Dip Peel Resistance | — | The accumulative length of single side glue line tackless less than 1/3 length of the glue line(less than 3mm not count), the number of qulified products | 0,0,0,0 0,0,0,0 0,0,0,0 0,0,0,0 0,0,0,0 0,8,0,0 | Qualified | 0,0,0,0 0,0,0,0 0,0,0,0 0,0,0,0 0,0,0,0 0,0,0,0 | Qualified | 0,0,0,0 0,5,0,0 0,0,0,0 0,0,0,0 0,0,0,0 0,0,0,0 | Qualified | ||
Static Bending Strength | MPa | ≥30 | 102.9 | Qualified | 15.3 | Unqualified | 52.7 | Qualified | ||
Water Content Rate | % | 4~12 | 8.4 | Qualified | 0.7 | Unqualified | 10.1 | Qualified | ||
UV Painting Adhesion | — | No peeling of paint at the intersection of cut marks and cut marks | Small amount peeling of paint at the intersection of cut marks and cut marks | A small amount | Qualified | A small amount | Qualified | No peeling | Qualified | |
Abrasion Resistaance ( Finished Surface ) | g/100r | ≤0.08,paint film unworn | ≤0.15,paint film unworn | 0.074, unworn | Qualified | 0.069, unworn | Qualified | 0.090, unworn | Qualified | |
Surface Pollution Resistance | — | No pollution trace | No pollution trace | Qualified | No pollution trace | Qualified | No pollution trace | Qualified | ||
Water Swelling rate of Thickness | % | ≤20 | 5.1 | Qualified | 0.1 | Qualified | 4.3 | Qualified | ||
Interal bond streng | Mpa | ≥0.8 | 1.8 | Qualified | 1.7 | Qualified | 1.6 | Qualified | ||
Dimensional Stability (water resistance) | mm | ≤0.9 | 0.45 | Qualified | 0.08 | Qualified | 0.21 | Qualified | ||
Formaldehyde Emssion | mg/L | E0:≤0.5;E1≤1.5 | 0.78 | Qualified | 0.16 | Qualified | 0.35 | Qualified | ||
General Conclusion | According to LY/T1739-2009 Wooden Flooring test,VHP flooring & Traditional Engineered Flooring meets the standard . WSPC flooring can't meets the testing of Static Bending Strength & Water Content Rate |
Test Item | Unit | Standard | VHP flooring (7mm) | WSPC(One face6mm) | Engineered flooring (15mm) | |||||
Test value | Assessment | Test value | Assessment | Test value | Assessment | |||||
Heat Dimensional Stability | Length direction | % | ≤0.30 | 0.23 | Qualified | 0.24 | Qualified | 0.2 | Qualified | |
Width direction | % | ≤0.40 | 0.34 | Qualified | 1.76 | Unqualified | 0.18 | Qualified | ||
Conclusion | According to LY/T1700-2018 Ground Heating system wooden flooring test,VHP flooring & Traditional Enginnered Flooring meets the standard . The width direction of WSPC can't meets the standard |
Test Item | Unit | Standard | VHP flooring (7mm) | WSPC (6mm) | Engineered flooring (15mm) | |||||
Test Result | Conclusion | Test Result | Conclusion | Test Result | Conclusion | |||||
Warping | mm | ≤2 | 2 | Qualified | 38 | Unqualified | ` | Qualified | ||
General Conclusion | According to GB/T4085-2015 semi-rigid PVC plank floor test,VHP floor & Traditional Enginnered Flooring meets the standard . WSPC can't meets the standard |
Test Item | Unit | Standard | VHP flooring (7mm) | WSPC (One face6mm) | Engineered flooring (15mm) | |||||
Test value | Assessment | Test value | Assessment | Test value | Assessment | |||||
Heat Dimensional Stability | Length direction | % | ≤0.30 | 0.23 | Qualified | 0.24 | Qualified | 0.2 | Qualified | |
Width direction | % | ≤0.40 | 0.34 | Qualified | 1.76 | Unqualified | 0.18 | Qualified | ||
Conclusion | According to LY/T1700-2018 Ground Heating system wooden flooring test,VHP flooring & Traditional Enginnered Flooring meets the standard . The width direction of WSPC can't meets the standard |